通风工程,东莞通风工程,东莞通风净化工程,东莞环保空调,东莞厂房降温,工业环保空调排烟系统风口尺寸及数量计算?
排烟干管风速不大于10m/s,通风净化工程价格,风口风速不大于10m/s?
对于防烟分区排烟风口计算,取干管速度为8m/s,风口风速为8m/s,采用多叶防火排烟风口,通风净化工程多少钱,尺寸300mm×400mm,面积S=0.12m2?
Q1=11880m3/h=3.3m3/s?????????n1=3.3/(8×0.12)=3.4????????n1取3?Q2=27180m3/h=7.55m3/s????????n2=7.55/(8×0.12)=7.8???????n2取8?Q3=24516m3/h=6.81m3/s????????n3=6.81/(8×0.12)=7.0???????n3取7?防烟分区一:?
排烟口速度选8m/s,取3个排烟口,则每个排烟口的排烟量Q=11880/(3600×3=0.81m3/s?
F=Q/V=0.81/8=0.102m2?选取300mm×400mm单层百叶防火风口?V实际=0.81/0.12=6.75m/s?防烟分区二:?
排烟口速度选8m/s,取8个排烟口,则每个排烟口的排烟量Q=27180/(3600×8)=0.94m3/s?
F=Q/V=0.94/8=0.118m2?选取300mm×400mm单层百叶防火风口?V实际=0.94/0.12=7.8m/s?防烟分区三:?
排烟口速度选8m/s,取7个排烟口,则每个排烟口的排烟量Q=24516/(3600×7)=0.97m3/s?
F=Q/V=1.1/8=0.121m2?选取300mm×400mm单层百叶防火风口