摘要:本文介绍了安科瑞DJSF1352-RN直流电表在俄罗斯UPS计量系统中的应用。主要用于UPS系统中的输出电能的计量,通过霍尔对电路系统进行计量、通讯和控制等。
Abstract: This article introduces the application of “Acrel” DJSF1352-RN DC meter in the Russian UPS metering system. It is mainly used for the measurement of the output energy in the UPS system, and the measurement, communication and control of the circuit system through the Hall sensor.
1.项目概述:Project Overview
该公司位于俄罗斯,是一家电池生产公司。主要在俄罗斯从事工业电池及UPS的生产和供应。客户要使用直流电表,用于UPS输出端电能的监测计量。
The company is located in Russia and is a battery production company. Mainly engaged in the production and supply of industrial batteries and UPS in Russia. The customer needs to use a DC meter for monitoring and measuring the electrical energy at the output of the UPS.
2.DJSF1352-RN介绍 DJSF1352-RN DC Energy Meters
DJSF1352-RN导轨式直流电能表,主要针对电信基站、直流充电桩、太阳能光伏等应用场合而设计,该系列仪表可测量直流系统中的电压、电流、功率以及正反向电能等。在实际使用现场,即可计量总电能,又可计量规定时间段内的电能。检测的结果既可用于本地显示,又能与工控设备、计算机连接,组成测控系统。
仪表可具有红外通讯接口和RS-485通讯接口,同时支持Modbus-RTU协议和DLT645-97(07)协议;可带继电器警报输出和开关量输入功能;根据不同要求,通过仪表面板按键,对变比、警报、通讯进行设置;具有开关量事件记录(Modbus协议)、编程和事件设置记录(645协议)、数据瞬时和定时冻结功能(645协议)、电压电流功率峰值、谷值记录功能。
3.型号及功能介绍 Type and Function Description
Note:when dual DC input(D)function is selected,if Hall current sensor input is used in current channel, a power supply module shall be provided to supply power to the second Hall sensor; if D function is not provided, the built-in power supply of electric meter can be used.
Technical parameters | Index | ||||
Input | Nominal value | Voltage input range | Current input | ||
DC 0-1000V | Hall sensor:0-20mA、4-20mA、0-5V,0-10V and so on. | ||||
Overload | 1.2 times rated (continuous); 2 times rated/1 second; | ||||
Power consumption | Voltage: ≤0.2VA, current ≤0.1VA | ||||
Accuracy class | Class 1 | ||||
Function | Display | 8-bit segment LCD screen (LCD) | |||
Communication Interface | RS485(two options) | ||||
Communication protocol | Modbus-RTU,DL/T 645-2007 | ||||
Switch | Switch output | 2 Relay outputs, 2A/30VDC or 2A/250VAC | |||
Switch input | 2 dry contact inputs | ||||
Pulse output | A second pulse output, a energy pulse output | ||||
See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWh | |||||
Power Supply | Voltage range | AC/DC 85-265V or DC24V(±10%) or DC48V(±10%) | |||
Power consumption | ≤ 3W | ||||
Power frequency withstand voltage | Power supply // Voltage input // Current input // Relay output and switch input // Communication interface / / Pulse output 3kV/1min Power supply // Relay output // Voltage input // Current input 3kV/1min Pulse output // Communication interface // Switch input 2kV/1min | ||||
Impulse withstand voltage | ±6KV | ||||
Insulation resistance | ≥ 40M Ω | ||||
Average barrier-free working hours | ≥50000h | ||||
Environment | Temperature | Normal operating temperature: -25 °C ~ +65 °C; Limit working temperature: -40 °C ~ +70 °C; Storage temperature: -40℃~+80℃ | |||
Humidity | ≤93%RH, no condensation, no corrosive gas | ||||
Altitude | ≤2500m |
4.客户要求 Customer Requirements
客户想计量UPS的实际输出电能,来计算UPS储能与耗能的转化比,UPS输入端用的是我们ADL系列的电表,输出端用的是DJSF1352-RN直流电表,通过分流器采取电信号,达到输出端测量的目的
参考文献 Bibliography
1.Solutions For Enterprise Micro-grid System 2021.04
相关产品:多功能电表、导轨式智能电表、无线电表、4G电表、NB电表、电机保护器、马达保护器、线路保护器、预付费电表、无线测温、电房无人值守系统、配电室综合监控系统、电能管理系统、能耗管理系统、用电管理系统、能源信息化系统、预付费管理系统